4013E  High low temperature circulators 1
4013E  High low temperature circulators 1

4013E High low temperature circulators

This type thermostatic circulators integrates both heating and cooling functions. The water bath tank body is made of stainless steel, and the outside is insulated with insulating cotton. It is applicable to temperature control, material testing, quality control and analysis of samples. Adopts environment-friendly natural refrigeration. With liquid level protection and over temperature protection functions, it complies with the safety class III/FL and can use flammable liquid, which complies to the DIN 12876 standard

    oops...!

    no product data.

    Go to homepage
    Product features:
    Maintenance free pressure/suction pump, resistant to fiber and metal particles, and capable of stirring the bath in both horizontal and vertical directions for more uniform mixing. The pump pressure and flow rate automatically adapt to external loads;
    Multiple safety protections: Low liquid level protection, capable of alerting with both light and sound when an alarm is triggered.
    Parts that come into contact with liquids or vapors are made of high-performance stainless steel and high-performance plastics.
    Pt100 temperature sensor, capable of two-point and multi-point temperature calibration
    Detachable dust screen cover for air inlet, very easy to maintain
    The buzzer can be set to silent or audible
    Multiple operation modes are available, and automatic recovery is possible in case of unexpected power failure.
    1) Mode 1: When the power supply of the device is disconnected during operation, the next time the device is powered on, it will be in a normal stop state, and the set value can be changed.
    2) Mode 2: When the power is disconnected during device operation, the device will automatically run the next time it is powered on, and the set value can be changed.
    3) Mode 3: When the power is disconnected during device operation, the device will automatically run the next time it is powered on, and the set value cannot be changed.
    Optional intelligent control function: Multiple interfaces (RS485, RS232) for remote communication and control of device start and stop.
    Optional 0-10V or 4-20mA analog signal input, can be used for external intelligent device control of instrument start and stop.
    The device serial number can be checked through software

    Specifications

    Model

     Temp. range
    [ºC]  

    Temp. stability
    [ºC]  

    Heat power
    [W]  

    Pump flow
    [L/Min]

    Pump pressure
    [bar]

    Pump pressure
    [bar]

    Tank volume
    [L]

    Tank open size
    WxDxH[mm] 

    Overall dimensions
    WxDxH[mm]  

    HW-CHCmini-406

    -40...200

    ±0.02

    2000

    0...33.3

    0...0.7

    0...0.4

    6.0

    -

    -

    HW-CHC-1008E

    -10...100

    ±0.05

    2000

    12

    0.2

    -

    8.0

    166×140×150

    230×400×615

    HW-CHC-2005E

    -20...100 

    ±0.05

     2000

    12

    0.2

    0.1

    5.0

    166X38X150

    230X400X615

    HW-CHC-2008E

    -20...100

    ±0.05

    2000

    22

    0.3

    0.2

    8.0

    166×140×150

    230×400×615

    HW-CHC-4005E

    -40...100

    ±0.05

     2000

    22

    0.3

    0.2

    5.0

    166X38X150

    230X400X720

    HW-CHC-4008

     -40...100 

    ±0.05

     2000  

    22

    0.3

    0.2

    8.0

    166X140X150

    230X400X720

    HW-CHC-8005E

    -80...100

    ±0.05

    2000

    22

    0.3

    0.2

    5.0

    166X38X150

    350×570×778

    HW-CHC-8008E

    -80...100

    ±0.05

    2000

    22

    0.3

    0.2

    8.0

    166X140X150

    350×570×778

    HW-CHC-2013

     -20...100  

     ±0.05

     2000  

    12

    0.2

    0.1

    13.0

    290×145×150

    350×400×660

    HW-CHC-2017

     -20...100  

    ±0.05

     2000  

    22

    0.3

    0.2

    17.0

    290×145×200

    350×400×660

    HW-CHC-2020E

     -20...100

    ±0.05

     2000  

    22

    0.3

    0.2

    20.0

    295×297×150

    350X570X778

    HW-CHC-2027

     -20...100  

    ±0.05

     2000  

    22

    0.3

    0.2

    27.0

    295×297×200

    350X570X778

    HW-CHC-3020E

    -30...100

    ±0.05

    2000

    22

    0.3

    0.2

    20.0

    295×297×150

    350X570X778

    HW-CHC-3027E

    -30...100

    ±0.05

    2000

    22

    0.3

    0.2

    27.0

    295×297×200

    350X570X778

    HW-CHC-4013E

    -40...100

    ±0.05

    2000

    22

    0.3

    0.2

    13.0

    295×130×150

    350×450×720

    HW-CHC-4017E

    -40...100

    ±0.05

    2000

    -

    -

    -

    17.0

    295×130×200

    350×570×778

    HW-CHC-2005SM

    -20...150

    ±0.03

    2000

    22

    0.3

    0.2

    5.0

    166×38×150

    230X400X615

    HW-CHC-2008SM

    -20...150

    ±0.03

    2000

    22

    0.3

    0.2

    8.0

    166X140X150

    230X400X615

    HW-CHC-2013SM

    -20...150

    ±0.03

    2000

    22

    0.3

    -

    13.0

    350×400×660

    295×130×150

    HW-CHC-2017SM

    -20...150

    ±0.03

    2000

    22

    0.3

    0.2

    17.0

    290×145×200

    350×400×660

    HW-CHC-2020SM

    -20...150

    ±0.03

    2000

    22

    0.3

    0.2

    20.0

    295×297×150

    350×570×778

    HW-CHC-2027SM

    -20...150

    ±0.03

    2000

    22

    0.3

    0.2

    27.0

    295×297×200

    350×570×778

    HW-CHC-3020SM

    -30...150

    ±0.03

    2000

    22

    0.3

    0.2

    20.0

    295×297×150

    350×570×778

    HW-CHC-3027SM

    -30...150

    ±0.03

    2000

    22

    0.3

    0.2

    27.0

    295×297×200

    350×570×778

    HW-CHC-4005SM

    -40...150

    ±0.03

    2000

    22

    0.3

    0.2

    5.0

    166×38×150

    230X400X720

    HW-CHC-4008SM

    -40...150

    ±0.03

    2000

    22

    0.3

    0.2

    8.0

    166X140X150

    230X400X720

    HW-CHC-4013SM

    -40...150

    ±0.03

    2000

    22

    0.3

    -

    13.0

    350×450×720

    295×130×150

    HW-CHC-4017SM

    -40...150

    ±0.03

    2000

    22

    0.3

    -

    17.0

    295×130×200

    350×570×778

    HW-CHC-2005SH

    -20...200

    ±0.03

    2000

    22

    0.3

    0.2

    5.0

    166×38×150

    230X400X615

    HW-CHC-2008SH

    -20...200

    ±0.03

    2000

    22

    0.3

    0.2

    8.0

    166X140X150

    230X400X615

    HW-CHC-2013SH

    -20...200

    ±0.03

    2000

    22

    0.3

    0.2

    13.0

    290×145×150

    350×400×660

    HW-CHC-2017SH

    -20...200

    ±0.03

    2000

    22

    0.3

    0.2

    17.0

    290×145×200

    350×400×660

    HW-CHC-2020SH

    -20...200

    ±0.03

    2000

    22

    0.3

    0.2

    20.0

    295×297×150

    350×570×778

    HW-CHC-2027SH

    -20...200

    ±0.03

    2000

    22

    0.3

    0.2

    27.0

    295×297×200

    350×570×778

    HW-CHC-3020SH

    -30...200

    ±0.03

    2000

    22

    0.3

    0.2

    20.0

    295×297×150

    350×570×778

    HW-CHC-3027SH

    -30...200

    ±0.03

    2000

    22

    0.3

    0.2

    27.0

    295×297×200

    350×570×778

    HW-CHC-4005SH

    -40...200

    ±0.03

    2000

    22

    0.3

    0.2

    5.0

    166×38×150

    230X400X720

    HW-CHC-4008SH

    -40...200

    ±0.03

    2000

    22

    0.3

    0.2

    8.0

    166X140X150

    230X400X720

    HW-CHC-4013SH

    -40...200

    ±0.03

    2000

    22

    0.3

    -

    13.0

    295×130×150

    350×450×720

    HW-CHC-4017SH

    -40...200

    ±0.03

    2000

    22

    0.3

    -

    17.0

    295×130×200

    350×570×778

    HW-CHC-2005AH

    -20...200

    ±0.02

    2000

    0···33.3

    0...0.7

    0...0.4

    5.0

    166×38×150

    230×400×615

    HW-CHC-2008AH

    -20...200

    ±0.02

    2000

    0···33.3

    0...0.7

    0...0.4

    8.0

    166X140X150

    230×400×615

    HW-CHC-3013AH

    -30...200

    ±0.02

    2000

    0···33.3

    0...0.7

    0...0.4

    13.0

    290×145×150

    350×400×660

    HW-CHC-3020AH

    -30...200

    ±0.02

    2000

    0···33.3

    0...0.7

    0...0.4

    20.0

    295×297×150

    350×570×778

    HW-CHC-3027AH

    -30...200

    ±0.02

    2000

    0...33.3

    0.000.7

    0...0.4

    20.0

    295×295×150

    350×570×778

    HW-CHC-4005AH

    -40...200

    ±0.02

    2000

    0···33.3

    0...0.7

    0...0.4

    5.0

    166×38×150

    230×400×720

    HW-CHC-4008AH

    -40...200

    ±0.02

    2000

    0···33.3

    0...0.7

    0...0.4

    8.0

    166X140X150

    230×400×720

    HW-CHC-4013AH

    -40...200

    ±0.02

    2000

    0...33.3

    0...0.7

    0...0.4

    13.0

    295×130×150

    350×400×660

    HW-CHC-4017AH

    -40...200

    ±0.02

    2000

    0...33.3

    0...0.7

    0...0.4

    17.0

    295×130×200

    350×570×778

    HW-CHC-5008AH

    -50...200

    ±0.02

    3000

    0...33.3

    0...0.7

    0...0.4

    8.0

    166×140×150

    410×550×778

    HW-CHC-2008SHW

    -40...150

    ±0.03

    2000

    22

    0.3

    -

    17.0

    295×130×200

    350×570×778

    HW-CHC-2045SHW

    -20...200

    ±0.03

    3000

    22

    0.3

    0.2

    45.0

    300×300×320

    580×510×555

    We Supply After-Sales Service For 24 Hours, 7 Days Per Week.
    info@servereal-instruments.com
    +86-18014755745
    no data
    Related Products
    no data
    Profesional manufacturer & supplier for test equipment & analytical instruments since 2003.
    Contact Us
    Add: Suolide Science & Technology Industry Park, No.151, East Chunhui Road, Wuxi, China
    Contact Person:
    Mr. Patrick.Chuang
    info@servereal.com
    WhatsApp/wechat: +86-18014755745


    Copyright © 2025 Serve Real Instruments - | Sitemap
    Customer service
    detect