Main technical parameters
1. Maximum working temperature of furnace body: 300 ℃;
2. Average temperature zone size and temperature difference: 300 × three hundred × 300mm or 600 × three hundred × 600mm, ± 5 ℃ (two specifications optional);
3. Temperature control accuracy: ± 5 ℃ (at 300 ℃);
4. Effective volume (basket size): 300 × three hundred × 300mm or 600 × three hundred × 600mm (two sizes optional);
5. Heating up time of the cold furnace: 60 minutes (from room temperature to 300 ℃);
6. Temperature rise time of cold material entering the furnace: 5 minutes (300 ℃, material weight 7 kg);
7. Temperature control range of water tank: 15-50 ℃;
9. Temperature control accuracy: ± 2 ℃;
10. Water temperature unevenness: ± 2 ℃;
11. Temperature rise within 5 minutes of hot material entering water: ± 4 ℃ (material temperature 300 ℃, 7 kg);
12. Maximum power consumption of heating furnace: 6kw;
13. Maximum power consumption of water and electricity heater: 4kw;
14. Compressor power: 2.2kw;
15. Timer range: 0-120 minutes.
16. Equipped with an electric lifting and lowering device, convenient material transfer.
Instrument configuration: including one thermal shock tester host and one sample holder.
For ceramics with a water absorption rate greater than 10%, non immersion testing requires the selection of aluminum plates and aluminum particles, and the cost will be calculated separately.