Main technical parameters
The DRS series instruments are mainly used for detecting the thermal conductivity of insulation materials at high temperatures. DRS-3B has a vacuum atmosphere protection function to prevent sample oxidation.
DRS-4 and DRS-4A both use electric pressure and automatic thickness measurement. The difference is that the DRS-4 hot plate uses heat-resistant stainless steel, which has a slightly lower operating temperature, while the DRS-4A hot plate uses silicon carbide, which has a slightly lower pressure resistance. In addition, an additional thickness correction system is required for thickness measurement, but the temperature used on the hot surface is higher.
Model |
DRS-3 |
DRS-3A |
DRS-3B |
Thermal conductivity range |
0.0010-3W/mk |
0.0010-3W/mk |
0.0010-3W/mk |
Testing accuracy |
±5% |
±5% |
±5% |
Hot surface temperature range |
100-1200℃ |
100-1200℃ |
100-1200℃ |
Calorimetric temperature control method |
Thermostatic water tank |
Semiconductor refrigeration |
Semiconductor refrigeration |
Thermal protection and temperature control methods |
Semiconductor refrigeration |
Semiconductor refrigeration |
Semiconductor refrigeration |
Calorimetric plate size |
100×100(mm) |
100×100(mm) |
100×100(mm) |
Heat flow meter size |
100×100(mm) |
100×100(mm) |
100×100(mm) |
Sample temperature measurement points |
4 |
4 |
4 |
Sample atmosphere environment |
air |
air |
-0.095MPa;Atmosphere protection |
Sample size |
230×230~250×250(mm);thickness10~100(mm) |
||
Measurement control method |
Computer fully automated testing, data processing, and the ability to generate detection reports for printing and output |
||
Host power supply |
Voltage 220V; Frequency 50Hz; Total power ≤ 5KW |
||
Instrument configuration |
Including one DRS-3 testing host, one set of software, one set of testing thermocouples, one high-precision constant temperature water tank, and one desktop computer (can be provided by the purchaser) |
Including one DRS-3A testing host, one set of software, one set of testing thermocouples, one roll of rubber water pipe (instrument needs to be connected to tap water), and one desktop computer (can be provided by the purchaser). |
Including one DRS-3B testing host, one set of software, one set of testing thermocouples, one roll of rubber water pipe (instrument needs to be connected to tap water), one set of vacuum sealing device, one vacuum pump, and one desktop computer (can be provided by the purchaser). |
Optional items |
Multiple layers of testing can be selected according to customer requirements. For each additional layer tested, an additional testing thermocouple is required, and the cost will be calculated separately. |