Automatic calorimeter oxygen bomb method ISO 1928-1700536336550364 1
Automatic calorimeter oxygen bomb method ISO 1928-1700536336550364 1

Automatic calorimeter oxygen bomb method ISO 1928-1700536336550364

The automatic calorimeter is specially used to determine the gross calorific value (GCV)of coal, coke, petroleum, solid waste, cement black raw meal and other combustible substances.

 

 

    oops...!

    no product data.

    Go to homepage

    Features

      Five probes are used for real-time temperature sensing. During the test, the external cylinder, the internal cylinder, the temperature regulating water tank, the thermostatic water tank and the room temperature are detected in real time, so as to truly realize the automatic temperature adjustment of the internal and external cylinders;

    The MCPC control module is used to monitor the status of the instrument in real time, save the instrument parameters, and the test process is completed independently without the intervention of the upper computer, realizing offline operation and self diagnosis reminder of the instrument, greatly improving the reliability of the instrument;

    New automatic oxygen charging and venting device and automatic lifting mechanism of oxygen bomb are adopted, which can automatically lift and release oxygen, with high degree of automation and simple and convenient operation;

    The automatic identification technology of oxygen bomb is adopted to automatically distinguish the heat capacity of different oxygen bombs;

    The pump circulation mode is adopted to make the temperature of each point of the whole calorimetric system of the instrument fairly balanced, so as to ensure the accuracy of the test results;

    Thermal insulation materials are used to isolate the influence of external environment, and the instrument has strong anti-interference ability;

    The probe type electronic measuring cup is used to automatically measure the water volume of the inner cylinder. The repetition error is less than 0.5g, and the water volume of the inner cylinder is accurate and stable. The test time is short and the results are accurate;

    Automatic judgment function of ignition wire, which can accurately judge the bad state of ignition wire;

    Digital barometer is used to facilitate observation;

    Filter device for test water is used to prevent impurities from blocking the water path;

    According to the working conditions of the laboratory, it can be converted from desktop to vertical structure;

    It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded;

    For solid waste samples, special oxygen bomb, crucible and other accessories can be selected;

    The optional oxygen bomb gas collection device is used to collect the gas in the oxygen bomb.


    Specifications

    Model

    MJ-CV-OB-6

    MJ-CV-OB-5

    MJ-CV-OB-4

    Temperature measuring range

    5℃~40

    5℃~40

    5℃~40

    Precision

    RSD0.1%

    RSD0.1%

    RSD0.1%

    Thermal capacity stability

    Change of heat capacity within one year0.2%

    Change of heat capacity within one year0.2%

    Change of heat capacity within one year0.2%

    Accuracy

    Better than accuracy required in standard

    Better than accuracy required in standard

    Better than accuracy required in standard

    Temperature resolution

    0.0001

    0.0001

    0.0001

    Single sample test time

    13min(traditional method),10min(fast)

    13min(traditional method),10min(fast)

    13min(traditional method),10min(fast)

    Temperature sensing technology

    Oxygen bomb identification

    /

    MCPC module

    /

    Water level visibility

    /

    Oxygen charging mode

    Automatic

    Manual

    Automatic

    Exhaust mode

    Automatic

    Manual

    Automatic

    Lifting cover opening

    Automatic

    Automatic

    Automatic

    Water volume of outer barrel

    22L

    22L

    22L

    Refrigerating water volume

    12L

    12L

    8L

    Refrigeration mode

    Semi-conductor

    Semi-conductor

    Compressor

    Placement method

    Desktop, vertical

    Desktop, vertical

    Desktop

    Working power supply

    AC220V±22V/50Hz

     

     

    Power

    0.8 kW

     

    0.5kw

    Overall dimension (mm)

    980×520×500

     

    830×460×470

    Total weight 

    115 kg

    105 kg

    77 kg










    We Supply After-Sales Service For 24 Hours, 7 Days Per Week.
    info@servereal-instruments.com
    +86-18014755745
    no data
    Related Products
    no data
    Profesional manufacturer & supplier for test equipment & analytical instruments since 2003.
    Contact Us
    Add: Suolide Science & Technology Industry Park, No.151, East Chunhui Road, Wuxi, China
    Contact Person:
    Mr. Patrick.Chuang
    info@servereal.com
    WhatsApp/wechat: +86-18014755745


    Copyright © 2025 Serve Real Instruments - | Sitemap
    Customer service
    detect