The DRX-3 thermal conductivity tester adopts the transient hot wire method and parallel line method, mainly measuring the thermal conductivity, thermal conductivity (thermal diffusion coefficient), and specific heat capacity of solid and powder materials at different temperatures. Featuring high precision, high resolution, and high reproducibility. Automatically measured by computer control. Widely applicable for measuring the thermal conductivity of materials in research institutions, quality inspection, factories and mines, and other departments.

Standard:

GB/T 5990-2006 "Test method for thermal conductivity of shaped insulating refractory products (hot wire method)";

GB/T 17106-1997 "Test method for thermal conductivity of refractory materials (parallel line method)"; 

    oops...!

    no product data.

    Go to homepage

    Main technical indicators

    1. Measurement range: 0.015~25.0 W/(m · K)

    2. Temperature range: -40~120 (requires high and low temperature constant temperature box) with copper constantan hot wire

    Room temperature~1000 (requires distribution of resistance wire furnace) with nickel chromium nickel silicon or platinum platinum rhodium hot wire

    Room temperature~1300 (requires silicon carbide rod resistance furnace) with platinum platinum rhodium hot wire

    Room temperature~1600 (requires silicon molybdenum rod resistance furnace) with platinum platinum rhodium hot wire

    3. Measurement accuracy:<± 5.0%

    4. Sample size: 2 pieces not less than 40mm × 80mm × A cylinder composed of 114mm symmetrical rectangular prism or two semi cylindrical blocks with a cross-sectional diameter of not less than 80mm and a length of not less than 114mm stacked together; (or customized according to user requirements),

    5. Temperature resolution: 0.001

    6. Hotline power supply: current resolution 0.1mA, voltage resolution 0.1mV

    7. Equipment power supply: voltage 220V; Frequency 50Hz; Power 500W (refer to the instruction manual of the electric furnace temperature controller for the requirements of using the electric furnace temperature controller power supply)

    Standard configuration:

    including one DRX-3B testing host, one software, one set of communication interface and data cable, one desktop computer, and one set of parallel hotlines for room temperature testing. Additionally, a constant temperature device and high-temperature wire heating are optional and configured according to the contract.

     

    We Supply After-Sales Service For 24 Hours, 7 Days Per Week.
    info@servereal-instruments.com
    +86-18014755745
    no data
    Related Products
    no data
    Profesional manufacturer & supplier for test equipment & analytical instruments since 2003.
    Contact Us
    Add: Suolide Science & Technology Industry Park, No.151, East Chunhui Road, Wuxi, China
    Contact Person:
    Mr. Patrick.Chuang
    info@servereal.com
    WhatsApp/wechat: +86-18014755745


    Copyright © 2025 Serve Real Instruments - | Sitemap
    Customer service
    detect