Model |
LQ-XD-1000A
|
Volume |
1000L
|
Inner dimensions |
W(1000)mm × H(1000)mm × D(1000)mm |
External dimensions |
W(1600)mm × H(2350)mm × D(1700)mm |
Test environment conditions |
The ambient temperature is+5~+28 ℃, and the relative humidity is ≤ 85%. |
Testing methods |
National standard GB/T16422.1, American standard AATCC TM16 ASTM C1442. |
Xenon lamp power long arc xenon lamp |
2.5KW X (6) pieces. |
The irradiation intensity/wavelength (optional) |
0.30~0.65W/m2 (at 340nm) adjustable. 0.5-1.4W/m2 (at 420nm) adjustable. 300~650W/m2 (at 290-800nm) adjustable. Other bands can be customized. |
Radiation intensity regulation |
Computer+PID+digital power supply+xenon lamp stepless adjustment. |
Radiation intensity measurement |
Equipped with a sun eye, fully automatic measurement and control of irradiance values set by the user. |
Filter |
1. S1 high-purity quartz glass, so that the spectral stop value of irradiance on the sample is similar to the value of ground sunlight. 2. Modular design, which can optimize the combination according to the testing space, making it very convenient to replace the lamp tubes. 3. Depending on the environment, you can choose to simulate direct sunlight or window glass to transmit sunlight. 4. Unless the filter is damaged, there is generally no need to replace the filter. |
Blackboard (BPT) or Black Label (BST) temperature range |
Adjustable from room temperature+10 ℃ to 100 ℃. |
Temperature accuracy |
±3.0℃
|
Humidity range |
Exposure cycle 10% R H-70% R H is adjustable. Dark cycle 20% R H-98% R H is adjustable. |
Humidity accuracy |
±5.0 %R.H。 |
Distance from arc center to tray |
200-500mm adjustable. |
Dark cycle, irradiation cycle |
0-9999H adjustable |
Rain cycle |
0-9999min adjustable |
Box Structure |
Design of testing area, lamp maintenance area, instrument and electrical control area, and computer room partition, modular combination, to meet the humanized operation of testing and maintenance. |
Cabinet material |
Outer liner material: High quality color steel plate electrostatic spraying Inner liner material: high-quality heat-resistant and cold resistant stainless steel plate |
Test box door |
Single hinged door (facing the box, left hinge, right handle) with silicone rubber emergency sealing device. |
Water supply system |
Automatically replenish water after adding water in a drawer or connecting to a water source. |
Microcomputer controller |
7 inches, 800 × 480 dot matrix, TFT color LCD display. |
Operation mode |
Support program and fixed value methods. |
Setting method |
Chinese and English menus (can be freely selected), touch screen input |
Program capacity |
Program: Maximum of 120 groups Number of segments: The maximum number of segments is 14400 Number of loops: Maximum infinite loops |
Curve recording function |
PAM with battery protection, capable of saving device settings, sampling values, and sampling time; The maximum recording time is 180 days (when the sampling period is 60S). |
Auxiliary functions |
1.Fault alarm and cause, handling prompt function 2.Power outage protection function 3.Upper and lower limit temperature protection function 4.Calendar timing function (automatic start and automatic stop) 5. Self diagnosis function |