Full Automatic Fluoride Chloride Ion Tester 1
Full Automatic Fluoride Chloride Ion Tester 1

Full Automatic Fluoride Chloride Ion Tester

Model: MJ-FL-01

Standards: GB/ T4633-2014, GB/ T3558-2014

    oops...!

    no product data.

    Go to homepage

    Equipment features

    Equipped with automatic titration software, it can be used in the latest WIN10 computer operating system.

    The titration solution can be set, and the titration speed can be set at will according to the sample characteristics.

    It can directly read the titration milliliters and millivolts, and display the titration curve of the titration process. The experimental process does not require manual intervention, and the measurement results are automatically generated.

    The software has a built-in database, and the experimental data can be exported, printed and queried.

    High precision titration system is adopted to make titration control more accurate.

    Intelligent automatic titration, which can change the titration speed according to the change of potential, without manual intervention.

    It has the function of automatically stopping titration. When the instrument detects the potential end point, it automatically stops, saving resources and time.

    It has the function of pausing the experiment process, which is convenient and practical.

    With one button full speed cleaning function, it saves time and effort after the experiment.

    With mixing adjustment function, the mixing speed can be adjusted at will.

    The original solution collection module is used to make the control more accurate.

    The novel and reasonable appearance design not only makes the experiment more beautiful and convenient.

    It has a number of independent intellectual property rights to provide protection.

    Specifications

    Temperature measurement accuracy

    0.1

    Control accuracy

    1100±1

    Heating time

    25mins to reach 1100±1

    Temperature setting range

    100℃~1200

    Potential resolution

    0.1mV

    Setting range of current opening

    0200

    Test method

    High temperature combustion hydrolysis method

    Fluorine measurement range

    102000ug/g

    Chlorine measuring range

    0.003%45%

    Power supply

    AC220V±10%,50Hz

    Overall power

    3.5KW

    Operating Weight

    60kg

    Titration system size

    728*421*454

    Overall dimensions

    1066mm* 550mm* 675mm

    We Supply After-Sales Service For 24 Hours, 7 Days Per Week.
    info@servereal-instruments.com
    +86-18014755745
    no data
    Related Products
    no data
    Profesional manufacturer & supplier for test equipment & analytical instruments since 2003.
    Contact Us
    Add: Suolide Science & Technology Industry Park, No.151, East Chunhui Road, Wuxi, China
    Contact Person:
    Mr. Patrick.Chuang
    info@servereal.com
    WhatsApp/wechat: +86-18014755745


    Copyright © 2025 Serve Real Instruments - | Sitemap
    Customer service
    detect